beautypg.com

J.P. Instruments EDM 700/800/711 Pilots Guide User Manual

Page 15

background image

For Your Safe Flight

Page 11

Section 3 - Operating Procedures

Diagnostic Testing on Startup and During Flight

When your EDM is first turned on, all digits light up for a few seconds,
permitting you to check for non-functional segments. Then each column
is self-tested in sequence while the EDM tests internal components,
calibration and integrity of the probes. If a problem is found, it will be
displayed as

OPEN PRB or CAL ERR, followed by the name of the probe or

channel.

Display

Channel

Display

Channel

Display

Channel

EGT I

EGT #1

CHT I

CHT #1

OIL

Oil

EGT 2

EGT #2

CHT 2

CHT #2

TIT I

TIT #1

EGT 3

EGT #3

CHT 3

CHT #3

TIT2

TIT #2

EGT 4

EGT #4

CHT 4

CHT #4

CDT CRB

CDT carb

EGT 5

EGT #5

CHT 5

CHT #5

IND

IAT

EGT 6

EGT #6

CHT 6

CHT #6

OAT

OAT

During flight, probes are constantly checked for inconsistent or
intermittent signals. A faulty channel or probe encountered during start-
up or during flight will be deleted from the sequence, producing a
missing column or blank digital data.

Modes

The EDM has three different operating modes: Automatic, Manual and
LeanFind. When you first turn on the power the EDM starts in the
Manual mode, but will enter the Automatic mode after a few minutes.
The Automatic mode provides you with engine monitoring information
for the majority of flight conditions. To adjust the mixture, use the
LeanFind mode. And to display specific parameters, use the Manual
mode. In both the Automatic and Manual modes the analog display
shows a bar graph of EGT and CHT for each cylinder and the TIT and
Oil temperature.

Automatic Mode

Just tap the LF button, then tap the STEP button. No user
intervention is required to use this mode. In the Automatic mode the
EDM displays the parameter sequence at a user-selected rate (see
“Personalizing” on page 33).

Individual parameters can be excluded from the Automatic mode
(exclusion does not apply to the EDM-711): tap STEP to enter the
Manual mode. Tap STEP to index to the parameter you want to exclude.