Vent installation – Mueller Pre-Fab User Manual
Page 99

www.muellerinc.com
G-7
venT InsTallaTIon
Fasteners
(2 required
on each
side of vent)
Outside closure
with tape sealer
top and bottom.
(Field notch
around end
skirt gutter).
Vent
Vent
End Skirt
End Skirt
Roof Panel
Roof Panel
Vent End Cap
Blind Rivets (4 required)
Blind Rivets (4 required)
End Skirt
End Skirt Gutter
End Skirt Gutter
Fasteners
Sealant Tape
Remove this area
Scribe
4:12
3:12
2:12
End Skirt, attach to
leading vent
Outside closure with
tape sealer top and
bottom. (Field notch
around end skirt gutter).
Roof Pitch Greater Than 1:12
End cap is factory pre-cut to 1:12. The three dots
embossed in the end cap represent 2:12, 3:12
and 4:12 roof pitches. Select the appropriate dot
to represent the roof pitch, scribe two lines from
lower corners of the end cap, intersecting at the
dot. Remove the area described by the cribe
lines and install the end skirt.
section a
section a
section b
section b