SkyTrak 8042 Service Manual User Manual
Page 153

8-9
6036, 6042, 8042, 10042, 10054
Hydraulic System
8
C
Auxiliary
Hydraulics
3000 psi
(207 bar)
With engine at low idle, move auxiliary control lever left or
right. Hold auxiliary control lever over relief and check
pressure. If pressure is incorrect, check unloader pressure
per location 2. If location 2 is ok, check port reliefs on the
aux section of main control valve.
Test
Location
Adjust.
Location
Component
Description
Pressure
Reading
Pressure Test Procedures