5

Control Panel Settings

5-26

200/250/350

Cont

ro

l P

ane

l S

e

tt

ing

s

Cha

p

ter 5

2

Reminder

When turning the machine off, then on again with the main power switch,
wait about 10 seconds to turn the machine on after turning it off. The ma-
chine may not operate correctly if it is turned on immediately after being
turned off.

Specifying settings for address input and broadcast transmissions
(mode 018)

Select whether or not recipients can be specified by directly entering their
address, and select whether or not broadcast transmissions are permitted.

Settings at time of purchase

Specifying the setting

During the production of this unit, the settings in the shaded cells were se-
lected.

*1

Prohibited when bit 6 of software switch setting mode 477 is set so that

the settings can only be specified in Administrator mode

Bit

7 6 5 4 3 2 1 0

Setting

0 0 0 0 0 0 0 1 (HEX: 01)

Bit

Description

Setting

Description

Page
Reference

7, 6, 5, 4

----------

0000

*Do not change these
bits when specifying set-
tings for this function.

----------

3

Specifies whether or not a
destination can be speci-
fied by directly entering its
address.

* 1

0

Permitted

----------

1

Prohibited

2

Specifies whether or not
broadcast transmissions
are permitted.

0

Permitted

----------

1

Prohibited

1, 0

----------

01

*Do not change these
bits when specifying set-
tings for this function.

----------

This manual is related to the following products: