CS5467

38

DS714F3

8.3.16 System Gain (G)

Address: 28

Default = 1.25

System Gain (G) is applied to all channels. By default, G = 1.25, but can be finely adjusted to compensate for
voltage reference error. It is a two's complement value in the range of -2.0

 value  2.0, with the binary point

to the right of the second MSB. Values should be kept within 5% of 1.25.

8.3.17 System Time (Time)

Address: 29

Default = 0

System Time (Time) is measured in output word rate (OWR) samples. This is an unsigned integer in the range
of 0 to 16,777,215 samples. At OWR = 4.0 kHz, OWR will overflow every 1 hour, 9 minutes, and 54 seconds.
Time

can be used by the application to manage real-time events.