8.3.5 Mode Control (Modes)

Address: 16

Default = 0

VFIX

Use internal RMS voltage reference instead of voltage input for average active power.

0 = Use voltage input.
1 = Use internal RMS voltage reference, VF

RMS.

E1MODE[1:0]

E1, E2, and E3 alternate output mode (when enabled by E2MODE).

00 = E1, E2 = P1

AVG

, P2

AVG

01 = E1, E2 = S1, S2
10 = E1, E2 = Q1

AVG

, Q2

AVG

11 = E1, E2 = Q1

WB

, Q2

WB

E2MODE[1:0]

E2 Output Mode

00 = Energy Sign
01 = Total Apparent Energy
10 = Not Used
11 = Enable E1MODE

VHPF2:IHPF2

High-pass Filter Enable for Energy Channel 2

00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current

VHPF1:IHPF1

High-pass Filter Enable for Energy Channel 1

00 = No Filter
01 = HPF on Current, PMF on Voltage
10 = HPF on Voltage, PMF on Current
11 = HPF on both Voltage and Current

E3MODE[1:0]

E3 Output Mode (with E1MODE disabled)

00 = Total Reactive Energy (default)
01 = Power Fail Monitor
10 = Voltage1 Sign
11 = Total Apparent Energy

E3MODE[1:0]

E3 Output Mode (with E1MODE enabled)

00 = Power Fail Monitor
01 = Energy Sign
10 = Not Used
11 = Not Used

POS

Positive Energy Only. Suppresses negative values in P1

AVG

and P2

AVG

. If a negative value

is calculated, zero will be stored instead.

AFC

Enables automatic line frequency measurement which sets Epsilon every time a new line

frequency measurement completes. Epsilon is used to control the gain of the 90 degree
phase shift integrator used in quadrature power calculations.

23

22

21

20

19

18

17

16

-

VFIX

-

-

-

-

-

-

15

14

13

12

11

10

9

8

-

E1MODE1

E1MODE0

-

-

E2MODE1

E2MODE0

VHPF2

7

6

5

4

3

2

1

0

IHPF2

VHPF1

IHPF1

-

E3MODE1

E3MODE0

POS

AFC