3 host port timing - intel® mode, 3 host port timing - intel, Mode – Cirrus Logic CS1810xx User Manual
Page 26
26
©
Copyright 2005 Cirrus Logic, Inc.
DS651UM23
Version 2.3
CobraNet Hardware User’s Manual
Host Management Interface (HMI)
7.3 Host Port Timing - Intel
®
Mode
(C
L
= 20 pF)
NOTES:1. The system designer should be aware that the actual maximum speed of the communication port may
be limited by the firmware application. Hardware handshaking on the HREQ pin/bit should be observed
to prevent overflowing the input data buffer.
Parameter
Symbol
Min
Max
Unit
Address setup before HCS and HRD low or HCS and HWR
low
t
ias
5
-
ns
Address hold time after HCS and HRD low or HCS and HWR
high
t
iah
5
-
ns
Read
Delay between HRD then HCS low or HCS then HRD low
t
icdr
0
-
ns
Data valid after HCS and HRD low
t
idd
-
18
ns
HCS and HRD low for read
t
irpw
24
-
ns
Data hold time after HCS or HRD high
t
idhr
8
-
ns
Data high-Z after HCS or HRD high
t
idis
-
18
ns
HCS or HRD high to HCS and HRD low for next read
t
ird
30
-
ns
HCS or HRD high to HCS and HWR low for next write
t
irdtw
30
-
ns
HRD rising to HREQ rising
t
irdirqhl
-
12
ns
Write
Delay between HWR then HCS low or HCS then HWR low
t
icdw
0
-
ns
Data setup before HCS or HWR high
t
idsu
8
-
ns
HCS and HWR low for write
t
iwpw
24
-
ns
Data hold after HCS or HWR high
t
idhw
8
-
ns
HCS or HWR high to HCS and HRD low for next read
t
iwtrd
30
-
ns
HCS or HWR high to HCS and HWR low for next write
t
iwd
30
-
ns
HWR rising to HREQ falling
t
iwrbsyl
-
12
ns