beautypg.com

6131h ai physical unit pv – WIKA D-21-9 User Manual

Page 31

background image

D-20-9 / D-21-9

GB

WIKA Additional Instructions Pressure Transmitter with CANopen Interface D-20-9 / D-21-9

31

6131h AI Physical Unit PV

Object description

This object defines the physical unit of the process value.

Entry description

Sub-Index

00h

Name

number of entries

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 8

Default Value

01h

Sub-Index

01h

Name

AI Physical Unit PV 1

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 32

Default Value

00 4E 00 00h

Data

MSB

LSB

Prefix

(always 0)

SI Numerator

SI-Denumerator

(always 0)

reserved

(always 0)

The following units are supported:

22h: Pascal
4Eh: bar
A1h: at
A2h: mmH

2

O

A3h: mHG
A4h: atm
ABh: PSI

The settings take effect after a reset.

Changed parameters are not automatically stored, but they have to be stored via object 1010h Store
Parameters.
Furthermore the device can be reset to the factory settings via object 1011h Restore Default Parameters.

This manual is related to the following products: