6124h ai input offset – WIKA D-21-9 User Manual
Page 29

D-20-9 / D-21-9
GB
WIKA Additional Instructions Pressure Transmitter with CANopen Interface D-20-9 / D-21-9
29
6123h AI Input Scaling 2 PV
Object description
This object defines the process value of the second calibration point for the analogue input channel. It is
scaled in physical unit of process value.
Entry description
Sub-Index
00h
Name
number of entries
Access
ro
PDO Mapping
No
Data Type
UNSIGNED 8
Default Value
01h
Sub-Index
01h
Name
AI Input Scaling 2 PV 1
Access
rw
PDO Mapping
No
Data Type
float
Default Value
No
Changed parameters are not automatically stored, but they have to be stored via object 1010h Store
Parameters.
Furthermore the device can be reset to the factory settings via object 1011h Restore Default Parameters.
6124h AI Input Offset
Object description
This object defines the additional offset value for the analogue input channel. It is scaled in physical unit of
process value.
Entry description
Sub-Index
00h
Name
number of entries
Access
ro
PDO Mapping
No
Data Type
UNSIGNED 8
Default Value
01h
Sub-Index
01h
Name
AI Input Offset 1
Access
rw
PDO Mapping
No
Data Type
float
Default Value
No