beautypg.com

2020h min. value storage, 2021h max. value storage, 2080h uncompensated ad-value – WIKA D-21-9 User Manual

Page 20

background image

D-20-9 / D-21-9

GB

WIKA Additional Instructions Pressure Transmitter with CANopen Interface D-20-9 / D-21-9

20

2020h Min. Value Storage

Object description

This object stores minimum process value. The storage is volatile.

Entry description

Access

rw

PDO Mapping

No

Data Type

float

Default Value

No

A write access clears the actual value.

2021h Max. Value Storage

Object description

This object stores maximum process value. The storage is volatile.

Entry description

Access

rw

PDO Mapping

No

Data Type

float

Default Value

No

A write access clears the actual value.

2080h Uncompensated AD-Value

Object description

This object contains the uncompensated pressure value of the A/D-converter.

Entry description

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 16

Default Value

No

Data

MSB

LSB

00h

00h

AD-value

This manual is related to the following products: