WIKA Additional Instructions Pressure Transmitter with CANopen Interface D-20-9 / D-21-9

17

1A00h Transmit PDO Mapping Parameter

Object description

This object contains the mapping for the PDO the device is able to transmit.
The subindex 0h contains the number of valid entries within the mapping record. This number of entries is also
the number of the application variables which shall be transmitted with the corresponding PDO.
The subindex 1h contains the information about the mapped application variable. This entry describes the
PDO contents by their index, sub-index and length. All three values are hexadecimal coded. The length entry
contains the length of the object in bit (20h).

Entry description

Sub-Index

00h

Name

number of entries

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 8

Default Value

04h

Sub-Index

01h

Name

1

st

. Mapped Application Object

Access

rw

PDO Mapping

No

Data Type

UNSIGNED 32

Default Value

2090 00 20 h

Changed parameters are not automatically stored, but they have to be stored via object 1010h Store
Parameters.
Furthermore the device can be reset to the factory settings via object 1011h Restore Default Parameters.

(See also: 1. Process Data Object)