beautypg.com

1018h identity object – WIKA D-21-9 User Manual

Page 15

background image

D-20-9 / D-21-9

GB

WIKA Additional Instructions Pressure Transmitter with CANopen Interface D-20-9 / D-21-9

15

1018h Identity Object

Object description

This object contains general information about the device. The Vendor ID (sub-index 1h) contains a unique
value allocated to each manufacturer (WIKA: 47h). The manufacturer-specific Product code (sub-index 2h)
identifies a specific device version (Product label: P#). The manufacturer-specific Revision number (sub-index
3h) consists of a major revision number and a minor revision number. The major revision number identifies a
specific CANopen behaviour. If the CANopen functionality is expanded, the major revision has to be
incremented. The minor revision number identifies different versions with the same CANopen behaviour. The
manufacturer-specific Serial number (sub-index 4h) identifies a specific device (Product label: S#).

Entry description

Sub-Index

00h

Name

number of entries

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 8

Default Value

04h

Sub-Index

01h

Name

Vendor ID

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 32

Default Value

00 00 00 47h

Sub-Index

02h

Name

Product Code

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 32

Default Value

No

Sub-Index

03h

Name

Revision Number

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 32

Default Value

No

Sub-Index

04h

Name

Serial Number

Access

ro

PDO Mapping

No

Data Type

UNSIGNED 32

Default Value

No

This manual is related to the following products: