Ptz aspect ratio lock, Byosdpipyget, Byosdpipysave – Kramer Electronics VP-790 User Manual
Page 99: Byosdptzaspectset

VP-790 Protocol –
API Functions
95
2.88.2
389B
byOsdPipYGet
API index: 3215
Retrieves the PiP Vertical Position from either cache or the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0 ... 100
PIP Vertical position in % of the main
image, i.e. 0% PiP top edge aligns
with main top edge and 100% PiP
bottom edge aligns with bottom edge.
2.88.3
390B
byOsdPipYSave
API index: 3216
Saves the PiP Position setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.89
97B
PTZ Aspect Ratio Lock
2.89.1
391B
byOsdPtzAspectSet
API index: 3237
Gives access to the vertical zoom slider for asymmetric zoom/shrink when Aspect
Lock is Off.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: On
1: Off
Switch Aspect Lock on or off.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise