Moving test pattern speed, Byosdtpgwidthsave, Byosdtpgspeedset – Kramer Electronics VP-790 User Manual
Page 75: Byosdtpgspeedget, Byosdtpgspeedsave

VP-790 Protocol –
API Functions
71
2.62.3
315B
byOsdTpgWidthSave
API index: 3298
Saves the line thickness of the moving test pattern from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.63
71B
Moving Test Pattern Speed
2.63.1
316B
byOsdTpgSpeedSet
API index: 3286
Sets the motion speed of the diagonally moving test pattern.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
1 .. 16
Motion Speed Set in Pixels (vertical
and horizontal) per VSync
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.63.2
317B
byOsdTpgSpeedGet
API index: 3287
Retrieves the motion speed of the diagonally moving test pattern.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
1 .. 16
Motion Speed setting
2.63.3
318B
byOsdTpgSpeedSave
API index: 3288
Saves the motion speed setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise