28 dvi input port configuration analog/digital, 1 byosddviiportset, 2 byosddviiportget – Kramer Electronics VP-790 User Manual
Page 42: 3 byosddviiportsave, Dvi input port configuration analog/digital

38
VP-790 Protocol - API Functions
2.28 DVI Input Port configuration analog/digital
2.28.1 byOsdDVIIPortSet
API index: 3300
Switches between processing of digital (TMDS) and analogue (VGA) input type
(DVI-D or DVI-A).
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: digital (DVI-D)
1: analogue (DVI-A)
Switches between digital and
analogue input processing.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.28.2 byOsdDVIIPortGet
API index: 3301
Retrieves the processing type for the DVI-I input port.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: digital (DVI-D)
1: analogue (DVI-A)
Retrieves the DVI-I port setting,
digital or analogue input processing.
2.28.3 byOsdDVIIPortSave
API index: 3302
Saves the DVI-I input port processing setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise