VP-790 Protocol - API Functions
2.50 IP Address
2.50.1 bySetStaticIPAddr
API index: 111
Sets the static IP address and saves the setting in the SPD immediately.
Input Parameters
Name
Type
Range
Description
Value
STRING
nnn.nnn.nnn.nnn
String with 15 ASCII
characters /0 terminated
Static IP address
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.50.2 byGetStaticIPAddr
API index: 112
Retrieves the IP address from the SPD.
Input Parameters
Name
Type
Range
Description
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
STRING
nnn.nnn.nnn.nnn
String with 15 ASCII
characters /0 terminated
Static IP address
2.51 IP Address Type
2.51.1 bySetDHCPStatus
API index: 115
Choose between IP address type static or DHCP leased and saves the setting in
the SPD immediately.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: Static
1: DHCP
IP address type
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise