Announce data repeat period, Byosdsetannouncerepeatperiod, Byosdgetannouncerepeatperiod – Kramer Electronics VP-790 User Manual
Page 25: Byosdsaveannouncerepeatperiod

VP-790 Protocol –
API Functions
21
2.10
18B
Announce Data Repeat Period
2.10.1
163B
byOsdSetAnnounceRepeatPeriod
API index: 4213
Set the period after which the announce message is automatically repeated.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0x0000-0x270F (or
decimal 0 ... 9999)
Repeat rate in seconds.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.10.2
164B
byOsdGetAnnounceRepeatPeriod
API index: 4212
Retrieves the IP address from the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0x0000-0x270F (or
decimal 0 ... 9999)
Repeat rate in seconds.
2.10.3
165B
byOsdSaveAnnounceRepeatPeriod
API index: 4214
Saves the Announce Message status from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise