64 multiple unit height, 1 byosdmultipleunitheightset, 2 byosdmultipleunitheightget – Kramer Electronics VP-790 User Manual
Page 76: 3 byosdmultipleunitheightsave, Multiple unit height

72
VP-790 Protocol - API Functions
2.64 Multiple Unit Height
2.64.1 byOsdMultipleUnitHeightSet
API index: 3103
Sets the number of units in vertical direction.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0x01-0x04
Number of units in vertical direction.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.64.2 byOsdMultipleUnitHeightGet
API index: 3104
Retrieves the number of units in horizontal direction.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0x01-0x04
Number of units set in vertical
direction.
2.64.3 byOsdMultipleUnitHeightSave
API index: 3105
Saves the number from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise