40 frame rate settings availability control, 1 byosdallowedframerateset, 2 byosdallowedframerateget – Kramer Electronics VP-790 User Manual
Page 54: 3 byosdallowedframeratesave, Frame rate settings availability control

50
VP-790 Protocol - API Functions
2.40 Frame Rate Settings Availability Control
2.40.1 byOsdAllowedFrameRateSet
API index: 3276
Makes 24/48Hz frame rate settings available.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: 50/60Hz
1: 24/50/60Hz
2: 48/50/60Hz
3: 24/48/50/60Hz
Ouput Mode Frame Rate availability
setting.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.40.2 byOsdAllowedFrameRateGet
API index: 3277
Retrieves the 24/48Hz Output Mode Frame Rate availability setting from either
cache or the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: 50/60Hz
1: 24/50/60Hz
2: 48/50/60Hz
3: 24/48/50/60Hz
Ouput Mode Frame Rate availability
setting.
2.40.3
byOsdAllowedFrameRateSave
API index: 3278
Saves the Output Mode Frame Rate availability setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise