116 vertical position, 1 byosdmainverticalset, 2 byosdmainverticalget – Kramer Electronics VP-790 User Manual
Page 124: 3 byosdmainverticalsave, Vertical position

120
VP-790 Protocol - API Functions
2.116 Vertical Position
2.116.1 byOsdMainVerticalSet
API index: 365
Sets the vertical position of the input image.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0 .. Vtotal-VSync-
Vbackporch
Vertical input position
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.116.2 byOsdMainVerticalGet
API index: 367
Retrieves vertical position from either cache or the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0 .. Vtotal-VSync-
Vbackporch
Vertical input position
2.116.3 byOsdMainVerticalSave
API index: 366
Saves the vertical position from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise