VP-790 Protocol –
API Functions
99
2.93
101B
PTZ Settings Scope
2.93.1
402B
byOsdPtzSettingSet
API index: 3222
Sets the scope of the PTZ settings from global to Per-mode.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: Use Globally
1: Use Per-Mode
Scope of PTZ settings.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.93.2
403B
byOsdPtzSettingGet
API index: 3223
Retrieves the PTZ scope setting from cache or from the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: Use Globally
1: Use Per-Mode
Scope of PTZ settings.
2.93.3
404B
byOsdPtzSettingSave
API index: 3224
Saves the PTZ scope setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise