87 pip size, 1 byosdabsolutepipsizesetsave, 2 byosdpipsizeget – Kramer Electronics VP-790 User Manual
Page 98: 88 pip v-pos, 1 byosdpipyset, Pip size, Pip v-pos

94
VP-790 Protocol - API Functions
2.87 PIP Size
2.87.1 byOsdAbsolutePipSizeSetSave
API index: 2974
Sets the PiP mode and saves the setting in the SPD immediately.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: Small
1: Medium
2: Large
PIP size
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.87.2 byOsdPipSizeGet
API index: 361
Retrieves the PiP size setting from either cache or the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: Small
1: Medium
2: Large
PIP size
2.88 PIP V-Pos
2.88.1 byOsdPipYSet
API index: 3214
Sets the PiP Vertical Position.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0 ... 100
PIP Vertical position in % of the main
image, i.e. 0% PiP top edge aligns
with main top edge and 100% PiP
bottom edge aligns with bottom edge.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise