Corner upper left corner, By4cornery4setvalue, Byosd4cornery4get – Kramer Electronics VP-790 User Manual
Page 19: By4cornerx1setvalue

VP-790 Protocol –
API Functions
15
2.4.3
144B
by4CornerY4SetValue
API index: 787
Moves the y-position of the lower right corner. The value is stored in cash and
SPD, there is no separate Save function.
Input Parameters
Name
Type
Range
Description
Value
SWORD32
-1000 .. +1000
Moves the y-position of the lower right
corner.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.4.4
145B
byOSD4CornerY4Get
API index: 741
Retrieves the position.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
SWORD32
-1000 .. +1000
Retrieves the position.
2.5
13B
4-Corner Upper Left Corner
The range (absolute) limit is -1000 to +1000. It is further limited by
the input and output mode resolution. If values not supported for a
given i/p o/p resolution combination are called the API will report
back an error code (0x9C).
2.5.1
146B
by4CornerX1SetValue
API index: 780
Moves the x-position of the upper left corner. The value is stored in cash and SPD,
there is no separate Save function.
Input Parameters
Name
Type
Range
Description
Value
SWORD32
-1000 .. +1000
Moves the x-position of the upper left
corner.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
i