I/o lock, Byosdiolockset, Byosdiolockget – Kramer Electronics VP-790 User Manual
Page 63: Byosdiolocksave

VP-790 Protocol –
API Functions
59
2.49
57B
I/O Lock
2.49.1
279B
byOSDIoLockSet
API index: 2978
Sets the Lock Type between PLL modulation and free run mode.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: Off
1: Source (locked to video input),
2:Genlock (locked to external source)
I/O Lock Type.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error
code otherwise
2.49.2
280B
byOsdIoLockGet
API index: 2979
Retrieves the I/O Lock Type either cache or the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: PLL On
1: PLL Off
I/O Lock Type
2.49.3
281B
byOsdIoLockSave
API index: 2980
Saves the I/O Lock Type setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise