Corner lower left corner, By4cornerx3setvalue, Byosd4cornerx3get – Kramer Electronics VP-790 User Manual
Page 17: By4cornery3setvalue

VP-790 Protocol –
API Functions
13
2.3
11B
4-Corner Lower Left Corner
2.3.1
138B
by4CornerX3SetValue
API index: 784
Moves the x-position of the lower left corner. The value is stored in cash and SPD,
there is no separate Save function.
Input Parameters
Name
Type
Range
Description
Value
SWORD32
-1000 .. +1000
Moves the x-position of the lower left
corner.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.3.2
139B
byOsd4CornerX3Get
API index: 738
Retrieves the position.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
SWORD32
-1000 .. +1000
Retrieves the position.
2.3.3
140B
by4CornerY3SetValue
API index: 785
Moves the y-position of the lower left corner. The value is stored in cash and SPD,
there is no separate Save function.
Input Parameters
Name
Type
Range
Description
Value
SWORD32
-1000 .. +1000
Moves the y-position of the lower left
corner.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise