beautypg.com

Pip mode, Byosdpiponoffset, Byosdpiponoffget – Kramer Electronics VP-790 User Manual

Page 95: Byosdpiponoffsave

background image

VP-790 Protocol –

API Functions

91

2.84

92B

PIP Mode

2.84.1

377B

byOsdPipOnOffSet

API index: 315
Sets the PiP mode.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: Off

1: PIP

2: PAP

3: POP

PIP mode

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.84.2

378B

byOsdPipOnOffGet

API index: 317
Retrieves the PiP mode setting from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0: Off

1: PIP

2: PAP

3: POP

PIP mode

2.84.3

379B

byOsdPipOnOffSave

API index: 316
Saves the PiP mode setting from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise