Pip mode, Byosdpiponoffset, Byosdpiponoffget – Kramer Electronics VP-790 User Manual
Page 95: Byosdpiponoffsave

VP-790 Protocol –
API Functions
91
2.84
92B
PIP Mode
2.84.1
377B
byOsdPipOnOffSet
API index: 315
Sets the PiP mode.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: Off
1: PIP
2: PAP
3: POP
PIP mode
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.84.2
378B
byOsdPipOnOffGet
API index: 317
Retrieves the PiP mode setting from either cache or the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: Off
1: PIP
2: PAP
3: POP
PIP mode
2.84.3
379B
byOsdPipOnOffSave
API index: 316
Saves the PiP mode setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise