108 select warp map slot, 1 byosdusermapset, 2 byosdusermapget – Kramer Electronics VP-790 User Manual
Page 116: 3 byosdusermapsave, Select warp map slot

112
VP-790 Protocol - API Functions
2.108 Select Warp Map Slot
2.108.1 byOsdUserMapSet
API index: 139
Selects the embedded warp API.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0: Off
1: Slot1
2: Slot2
...
8: Slot8
Switches on (1 to 8) the PC
generated free from warp map
processing and selects a warp map
being downloaded into the given slot.
With parameter 0 = off no warp map
is applied.
Slot 9 and Slot 10 are reserved for
Portrait 90 and Portrait 270 warp
maps.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.108.2 byOsdUserMapGet
API index: 141
Retrieves the number of the slot being selected.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0: Off
1: Slot1
2: Slot2
...
8: Slot8
Retrieves the number of the selected
slot.
2.108.3 byOsdUserMapSave
API index: 140
Saves the value from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise