Pip h-pos, Byosdpipxset, Byosdpipxget – Kramer Electronics VP-790 User Manual
Page 93: Byosdpipxsave

VP-790 Protocol –
API Functions
89
2.82
90B
PIP H-Pos
2.82.1
371B
byOsdPipXSet
API index: 3211
Sets the PiP Horizontal Position.
Input Parameters
Name
Type
Range
Description
Value
UWORD32
0 ... 100
PiP Horizontal position in % of the
main image, i.e. 0% PiP left edge
aligns with main left edge and 100%
PiP right edge aligns with main right
edge.
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
2.82.2
372B
byOsdPipXGet
API index: 3212
Retrieves the PiP Horizontal Position from either cache or the SPD.
Input Parameters
Name
Type
Range
Description
Option
BYTE
0: From cache
1: From SPD
Retrieval method
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise
Value
UWORD32
0 ... 100
PIP Horizontal position in % of the
main image, i.e. 0% PiP left edge
aligns with main left edge and 100%
PiP right edge aligns with main right
edge.
2.82.3
373B
byOsdPipXSave
API index: 3213
Saves the PiP Horizontal Position setting from cache into the SPD.
Input Parameters
None
Return Values
Name
Type
Range
Description
Status
BYTE
0x00-0xFF
0 if successful, error code otherwise