beautypg.com

Pip h-pos, Byosdpipxset, Byosdpipxget – Kramer Electronics VP-790 User Manual

Page 93: Byosdpipxsave

background image

VP-790 Protocol –

API Functions

89

2.82

90B

PIP H-Pos

2.82.1

371B

byOsdPipXSet

API index: 3211
Sets the PiP Horizontal Position.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0 ... 100

PiP Horizontal position in % of the

main image, i.e. 0% PiP left edge

aligns with main left edge and 100%

PiP right edge aligns with main right

edge.

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.82.2

372B

byOsdPipXGet

API index: 3212
Retrieves the PiP Horizontal Position from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0 ... 100

PIP Horizontal position in % of the

main image, i.e. 0% PiP left edge

aligns with main left edge and 100%

PiP right edge aligns with main right

edge.

2.82.3

373B

byOsdPipXSave

API index: 3213
Saves the PiP Horizontal Position setting from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise