beautypg.com

Overscan, Byosdoutputformatsave, Byosdoverscanset – Kramer Electronics VP-790 User Manual

Page 89: Byosdoverscanget

background image

VP-790 Protocol –

API Functions

85

2.77.3

358B

byOsdOutputFormatSave

API index: 325
Saves the Output Mode Resolution setting from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.78

86B

Overscan

2.78.1

359B

byOsdOverscanSet

API index: 2944
Sets the input overscan percentage.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: 0%

1: 2.5%

2: 5%

3: 7.5%

Overscan value

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

2.78.2

360B

byOsdOverscanGet

API index: 2945
Retrieves overscan setting from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise

Value

UWORD32

0: Standard

1: Full Screen

2: Crop

3: Anamorphic

Overscan value