byOsdCNRSet

API index: 251
Sets the level of the MNR (MPEG Codec noise reduction) algorithm.

Input Parameters

Name

Type

Range

Description

Value

UWORD32

0: Off

1: Low

2: Medium

3: High

MNR value

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code

otherwise

2.59.2

305B

byOsdCNRGet

API index: 253
Retrieves the level of the MNR from either cache or the SPD.

Input Parameters

Name

Type

Range

Description

Option

BYTE

0: From cache

1: From SPD

Retrieval method

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code

otherwise

Value

UWORD32

0: Off

1: Low

2: Medium

3: High

MNR value

2.59.3

306B

byOsdCNRSave

API index: 252
Saves the level of the CNR from cache into the SPD.

Input Parameters

None

Return Values

Name

Type

Range

Description

Status

BYTE

0x00-0xFF

0 if successful, error code otherwise