Kramer protocol – Kramer Electronics VP-8x8TP User Manual
Page 49

Kramer Protocol
45
45
Read audio volume level
AUD-LVL? STAGE, CHANNEL
Short form: ADL? STAGE
AUD-LVL STAGE,
CHANNEL, VOLUME
Parameters Description:
STAGE =
"In","Out"
or
Numeric value (present audio processing stage). For example: "0" for Input level, "1" for Pre-Amplifier, "2" for Amplifier (Out)
etc.
CHANNEL = Input or Output #
VOLUME
= Audio parameter in Kramer units, precede minus sign for negative values.
++
increase current value,
--
decrease current value.
MUTE MODE = 1 – Mute
0 – Unmute
Machine info commands
Command
Syntax
Response
* Time settings commands require admin authorization
Read in\outs count
INFO-IO?
INFO-IO: IN INPUTS_COUNT, OUT OUTPUTS_COUNT
Read max presets
count
INFO-PRST?
INFO-PRST: VID PRESET_VIDEO_COUNT, AUD
PRESET_AUDIO_COUNT
Reset configuration to
factory default
FACTORY
FACTORY RESULT
Mute Audio
MUTE MUTE MODE
MUTE MUTE MODE RESULT
Identification commands
Command
Syntax
Response
Protocol Handshaking
#CR
~OK CRLF
Read device model
MODEL?
MODEL MACHINE_MODEL
Read device serial number
SN?
SN SERIAL_NUMBER
Read device firmware version
VERSION?
VERSION MAJOR .MINOR .BUILD .REVISION
Set machine name
NAME MACHINE_NAME
NAME MACHINE_NAME RESULT
Read machine name
NAME?
NAME MACHINE_NAME
Reset machine name to factory
default*
NAME-RST
NAME-RST MACHINE_FACTORY_NAME RESULT
*Note: machine name not equal to model name. This name relevance for site viewer identification of specific machine or for
network using (with DNS feature on).