14 default edid, Default edid, The default edid is stored in all inputs – Kramer Electronics VP-8x8TP User Manual
Page 40

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Default EDID
36
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000
Front Panel:
Press and hold Output 1 and Output 3
simultaneously
Front Panel:
Press and hold Output 1 and
Output 2 simultaneously
Ethernet Factory Default Values
To reset the IP settings to the factory reset values, power cycle the device while holding in the Factory Reset
button, located on the rear panel of the unit
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
TCP Port #:
5000
UDP Port #:
50000
Maximum UDP Ports:
10
Maximum TCP Ports:
4
14
Default EDID
The default EDID is stored in all inputs.
Monitor
Model name
VP-8X8TP
Manufacturer
KRM
Plug and Play, ID
KRM0808
Serial number
2
Manufacture date
2009, ISO week 10
EDID revision
1.3
Input signal type
Analog 0.700, 0.000 (0.7 Vp-p)
Sync input support
Separate, Composite, Sync-on-green
Display type
RGB color
Screen size
360 x 290 mm (18.2 in)
Power management
Standby, Suspend, Active off/Sleep
Extension blocs
None
DDC/CI
Not supported
Color characteristics
Default color space
sRGB
Display gamma
2.0
Red chromaticity
Rx 0.611 - Ry 0.329
Green chromaticity
Gx 0.312 - Gy 0.559
Blue chromaticity
Bx 0.148 - By 0.131
White point (default)
Wx 0.320 - Wy 0.336
Additional descriptors
None
Timing characteristics
Range limits
Not available
GTF standard
Not supported
Additional descriptors
None
Preferred timing
Yes
Native/preferred timing
1024x768p at 60Hz (4:3)
Modeline
"1024x768" 65.000 1024 1048 1184 1344 768 771 777 806 -hsync –