8 using the ir transmitter, Using the ir transmitter, Ction 8 – Kramer Electronics VP-8x8TP User Manual

Page 27: On 8

background image

Operating Multiple VP-8x8TP Units Remotely via RS-232

23

23

3. Press either the (+) button or the minus (–) button to increase or decrease

respectively the audio gain setting.
The display changes accordingly.

4. Press the AUDIO LEVEL button to exit the gain level setting mode. If no

button is pressed for 40 seconds, the VP-8x8TP automatically exits the gain
level setting mode and the display reverts to normal operation.

7.8 Using the IR Transmitter

You can use the RC-IR3 IR transmitter to control the machine via the built-in IR
receiver on the front panel or, instead, via an optional external IR receiver1. The
external IR receiver can be located up to 15m (49ft) away from the machine. This
distance can be extended to up to 60m (196ft) when used with three extension
cables

2

Before using the external IR receiver, be sure to arrange for your Kramer dealer to
insert the internal IR connection cable

39F

3

with the 3.5mm mini connector that fits

into the REMOTE IR opening on the rear panel. Connect the external IR receiver
to the REMOTE IR 3.5mm mini connector.

8

Operating Multiple VP-8x8TP Units Remotely via RS-232

You can operate up to 16 VP-8x8TP units remotely via the RS-485 bus with
control from a PC or serial controller equipped with an RS-232 interface

40F

4

.

To operate up to 16 VP-8x8TP units remotely via RS-485 (see

Figure 14

):

1. Connect the sources and acceptors to the VP-8x8TP (see

Section 6.1

).

2. Connect the RS-232 port of the first VP-8x8TP unit to the PC or serial

controller.

3. Connect the RS-485 port on the first VP-8x8TP to the RS-485 port on the

second VP-8x8TP unit, and so on (see

Section 6.2

), connecting all the RS-485

ports.

4. Set the Machine number of the first VP-8x8TP to Machine number 1 (see

Section 6.2.2

).

5. Set the other VP-8x8TP units to be Machine numbers between 2 and 16.
6. On the first and last VP-8x8TP units, set the RS-485 TERM Dipswitch ON

(terminating the RS-485 line at 120

Ω) (see

Section 6.2

).

7. On all other VP-8x8TP units, set the RS-485 TERM Dipswitch OFF.

1 Model: C-A35M/IRR-50

2 Model: C-A35M/A35F-50

3 P/N: 505-70434010-S

4 Alternatively, the Ethernet port can be used for PC control (instead of RS-232)