9. PULSAlarm Leak Detection Assembly

The PULSAlarm leak detection assembly consists of a reagent head, leak detection
diaphragm, fill port, and pressure switch and gauge. The reagent head, diaphragm, suction
and discharge check valves are the only parts of the pump to contact the process liquid -
consequently, maintenance is critical to pump performance.

Figure 24

A

SEALED SYSTEM MUST BE MAINTAINED AT ALL TIMES DURING PUMP OPERATION

,

WHETHER LEAK DETECTION IS REQUIRED OR NOT

.

I

F A SEALED PRESSURE SYSTEM

IS NOT PRESENT

,

DECREASED FLOW AND

/

OR DIAPHRAGM DAMAGE WILL OCCUR

.

P

LEASE NOTE THAT THE FACTORY SET POINT FOR ACTUATION OF THE PRESSURE

SWITCH IS

25

PSIG

.