Draft 1 – Aastra Telecom 9480i Series User Manual
Page 756

Troubleshooting
9-10
41-001160-03, Rev 00, Releaes 2.4
IP Phone Administrator Guide
4
Click
to save your settings.
5
Click on Operation->Reset.
6
In the "Restart Phone" field click
to restart the IP phone.
To set blog modules:
7
Select a module for which you want to have log files created, and sent to a blog.
8
Enter a debug level value in the “Debug Level” field for a module. Valid values are:
The value of “0” turns all debug levels OFF for a module. The value of “65535” turns all debug levels
ON for a module.
To turn two or more debug levels on at the same time, you add the value associated with each level.
For example, Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7
log module linemgr: 7
log module user interface: 7
log module sip: 7
In the above example, fatal errors, general errors, and warnings are logged for the line manager, user
interface, and SIP call control modules.
9
Click
to save your settings.
Aastra Web UI
Step
Action
Debug Level
Value
Fatal Errors
1 (default)
Errors
2
Warnings
4
Init
8
Functions
16
Info
32
All debug
levels OFF
0
All Debug
Levels ON
65535
Draft 1