Cables

40DHB0002USCL – Issue 9 (28th October 2003)

V.35 WAN Cable

SAP Code:- 700213424

A

B

C

D

E


A 37 Way D-Type Plug with UNC 4-40 locking screws.
B 34 Way MRAC Plug.
C Label
D 10 twisted pair screened cable - each core is 7/0.203mm (24 AWG) tinned copper

stranded wire, nominal capacitance of 98pF/m, impedance of 80

Ω ± 10% at 1MHz,

screened with aluminized tape and a tinned copper wire drain.

E 3 meters/9.84ft.

Pin Connections

End A

Name

Cable Notes

End B

8

DTR (Data Terminal Ready)

-----

H

11

DCD (Data Carrier Detect)

-----

F

12

CTS (Clear To Send)

-----

D

27

RTS (Request To Send)

-----

C

29

RI (Ring Indicator)

-----

J

30

DSR (Data Set Ready)

-----

E

32

Transmit Data - A

P

14

Transmit Data - B

Twisted Pair

S

35

Receive Data - A

R

16

Receive Data - B

Twisted Pair

T

36

Transmit Clock - A

Y

17

Transmit Clock - B

Twisted Pair

AA

37

Receive Clock - A

V

18

Receive Clock - B

Twisted Pair

X

33

External Clock - A

U

15

External Clock - B

Twisted Pair

W

34 Ground

-----

B

Connect pins 7 and 25 to pin 6 at End A only.

Pin 19 at end A is connected to the Screened Cable Drain Wire.
The maximum core to core capacitance must not exceed 800pF.
This cable is used to connect a WAN port to a Digital leased Line.