background image

Installing a New System

Initial Assembly - Page 41

IP Office Installation Manual

Installing a New System - Page 41

40DHB0002USCL – Issue 9 (28th October 2003)

Initial Assembly

Installation of Voice Compression Modules (VCM)

Optional Voice Compression Modules (only one for IP 403/IP406 module and a max. of
two for IP412, see pages 10, 14 and 18 respectively) are fitted to an IP Office base unit as
follows:
Procedure
1. Remove the three fixing screws on the rear of cover.
2. Turn the unit over and remove the four fixing screws from the base.
3. Slide the cover from the unit.
4. Mount the VCM in position as shown below and secure with the two snap-in spacers.

Only an IP412 Office can accommodate a second VCM (of any type); the first module
can be mounted in either position.

5. Replace cover and secure with the seven fixing screws.

CAUTION: While installing, ensure that you wear a ground wrist strap that is connected

to a suitable grounding point.