beautypg.com

Ip400 analog trunk 16, Front view, Port connections – Avaya IP Office Phone User Manual

Page 27: Rear view, Protective ground (earth), Cables

background image

Expansion Modules

IP400 Analog Trunk 16 - Page 27

IP Office Installation Manual

Expansion Modules - Page 27

40DHB0002USCL – Issue 9 (28th October 2003)

IP400 Analog Trunk 16

IP400 Analog Trunk 16

Front View

Analog Trunk Ports 1-8

Unit Status LED
Red = Alive but not initiated
Green = Running OK

Analog Trunk Ports 9-16

Port connections

Analog Trunk Ports: These ports are used for connection to standard analog trunks

(loop start or ground start). Using standard structured wiring, these RJ45 ports can be
extended to the required trunk sockets.
Trunk ports 1 and 2 are, in the event of power failure, automatically switched to PF1
and PF2 respectively on the rear of the unit (see below).

Rear View

Expansion Port

DC Power I/P Socket

EXPANSION

DC I/P
- C +

24V DC
2A

PF2

PF1

Power Fail Trunks 1 & 2

Protective Earth Point

Port connections

Expansion Port: Used to connect the Analog Trunk Expansion Module an Expansion

Ports of an IP400 Office platform.

DC Power I/P Socket: Socket for the external 24V DC unregulated power supply

(supplied with kit).

Power Fail Trunks: These two ports must be set and connected to Loop Start trunks

only. POTs plugged into these two sockets are mapped to trunk ports 1& 2 such that,
in the event of a mains power failure, PF1 and PF2 can operate as 'hot lines' to the
emergency services (e.g. 911, etc).

Protective Ground (Earth)

Protective Grounding Point: Within the USA a protective grounding must be

permanently fitted. Connection of this protective grounding requires the use of suitable
tools and must be connected at both ends before connection is made to the
telecommunications network (see page 35).

Cables

IP400 Analog Trunk 16 is supplied with one blue Expansion Interconnect cable. For Port
Pinouts and Cables, refer to pages 63 and 67 respectively.