X.21 wan cable, Pin connections – Avaya IP Office Phone User Manual
Page 75
Technical Data
Cables - Page 75
IP Office Installation Manual
Technical Data - Page 75
40DHB0002USCL – Issue 9 (28th October 2003)
Cables
X.21 WAN Cable
SAP Code:- 700213408
A
B
C
D
E
A 37 Way D-Type Plug with UNC 4-40 locking screws.
B 15 Way D-Type Plug with M3 locking screws.
C Label
D 6 twisted pair screened cable - each core is 7/0.203mm (24 AWG) tinned copper
stranded wire, nominal capacitance of 98pF/m, impedance of 77
Ω at 1MHz, screened
with aluminized tape and a tinned copper wire drain.
E 3 meters/9.84ft.
Pin Connections
End A
Name
Cable Notes
End B
1 Receive
(Rx-B)
11
20 Receive
(Rx-A)
Twisted Pair
4
4 Transmit
(Tx-A)
2
23 Transmit
(Tx-B)
Twisted Pair
9
24 Control
(Ctl-A)
3
5 Control
(Ctl-B)
Twisted Pair
10
2 Indicate
(Ind-A)
5
21 Indicate
(Ind-B)
Twisted Pair
12
3 SE-Timing
(S-A)
6
22 SE-Timing
(S-B)
Twisted Pair
13
6 Ground
------
8
Connect pin 7 to pin 6 at End A only.
Pin 19 at end A is connected to the Screened Cable Drain Wire.
This cable is used to connect a WAN port to a Digital leased Line.