Konica Minolta QMS magicolor CX Reference User Manual
Page 30
Administration
Menu
QMS magicolor CX Reference Guide
1-22
Emulation
Sets the serial interface emulation.
Menu
Administration
Communications
Serial
Emulation
Choices
ESP (default), Hexdump, PostScript, PCL5,
HPGL, Lineprinter
Other optional emulations also appear, if
installed.
Min K Spool
Sets the minimum number of kilobytes of system memory
allocated to the serial interface.
Menu
Administration
Communications
Serial
Min K Spool
Choices
00000-99999
00015 (default)
Notes: This value must be less than K Mem For Spool.
A 00000 value does not turn off the spooling buffer for the serial interface.
If the value is set to 00000, the printer calculates the Min K Spool
automatically at initialization.
The printer must be restarted for changes to the Min K Spool menu to take
effect. You can either let the printer restart automatically after you save the
change and exit the Configuration menu, or you can wait for the change to
take effect the next time you manually turn on the printer.
Spooling Timeout
Sets the number of seconds the interface waits for data from the
host before terminating a spooled print job.
Menu
Administration
Communications
Serial
Spool Timeout
Choices
00000-99999
00030 (default)