Asante Technologies 1012 User Manual
Page 29

Page 1-17
Installing the AsantéBridge 1012
Turning on and Pretesting the Bridge
If you are installing more than one unit, you may want to repeat 
this procedure for each one before making any device or network 
connections.
Turning on the Bridge
1
Attach the power cord to the socket on the rear panel, and 
connect it to an AC outlet.
2
Turn on the power switch at the right rear panel.
Evaluating the self-test pattern
1
When you power up the AsantéBridge, it runs through a 
hardware and software self-test. All LEDs light and turn off, 
in groups of two or four, from right to left. This process 
takes about two seconds. 
2
If the unit does not pass the self-test, the LED displays stop 
at the detected error condition/test sector. 
If this occurs, reset the hub by depressing the recessed 
reset button using any pen-like instrument. If the self-test 
fails again, the unit has a hardware malfunction. In this 
case, note which LEDs are lit during the pause, and call 
Asanté Technical Support.
3
After the self-test is passed, the LEDs assume normal status. 
For a stand-alone hub, the PWR LED (green) is on and the 
SNMP and CPU LED is blinking. See “AsantéBridge 1012 
Front Panel” on page 1-6 for the location of these LEDs.
Pretesting the Link Connection
1
Connect an RJ-45 extension cable between front panel 
port #1 and the Ethernet interface port on a device config-
ured with Ethernet hardware and software. You can see the 
front panel LEDs respond to the connection.
The
LINK/RECEIVE LED
corresponding to port #1 turns
on. If the device is sending unacceptable packets, the Parti-
tion LED for that port may also blink, indicating that the 
hub has autopartitioned the port. The PWR and SNMP and 
CPU LEDs remain on and blink.