beautypg.com

Cable specifications, Overview – HID VertX Vx00 Installation Guide User Manual

Page 4

background image

November 2011

Page 4 of 10

© 2003 - 2011 HID Global Corporation. All rights reserved.

VertX V100, V200 and V300 Installation Guide

Cable Specifications

Cable Type

Length

Specification

RS-485 *

4000 feet (1220 m) to host

Using Belden 3105A, 22AWG twisted pair, shielded 100

Ω ca ble , or

equivalent.

Input Circuits *

500 feet (150 m)

2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C
(18AWG), or equivalent.

Output Circuits *

500 feet (150 m)

2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG),
or equivalent.

Wiegand

500 feet (150 m) to reader

ALPHA 1299C, 22AWG, 9-conductor, stranded, overall shield.

Fewer conductors needed if all control lines are not used.

Power Supply

+12 VDC IN

----

Refer to your Power Supply Installation Guide.

Minimum wire gauge depends on cable length and current requirements.

Overview

The following outlines what is required to installing VertX interface panels.