Set Primary Version

The M-ACC stores two software versions. The version which is currently running is
called the Primary version. A pointer (asterisk - *) shows which version is currently
the primary one.
To set a different primary version, select option 4 from the Setup Main Menu. A
menu similar to the following displays:

Primary Version Screen

M-ACCF S/W Version: 4.2.2 Slot #: 5

Refresh the screen

0. Return to Previous Menu

1. Save the Session

-----------------------------------

Select the Primary version

(The current primary is marked by *)

2. Version 1.0.3

3. * Version 1.0.1

>>>Enter your choice:

Once you select and save the desired primary version, you are prompted to reboot
the M-ACC. Type y and the M-ACC will set the pointer accordingly, and reboot
from the newly-defined primary version. If you don't wish to reboot at this time, the
pointer is saved, but the M-ACC continues running from the old version.

Set Defaults to Factory Settings

You can set the M-ACC’s configuration back to its default factory settings by
selecting item number 3 in the Module Setup Main Menu. The following
confirmation and warning messages are displayed:

*** Set default values ***, Confirm [y/n]?y

***WARNING*** - Management parameters were changed. Reset the agent!!

Before exiting this session, select the option Reset the M-ACC from the Module
Setup Main Menu.

Create Report

This command is intended for use by Avaya Technical Support personnel and provides
a comprehensive report of the status the M-ACC module of each port.