Maintenance – Blodgett SN-G Series User Manual
Page 18

16
OM-SN-G
Maintenance
The steamer is designed for minimum maintenance, and no user adjustments should
be necessary. Certain parts may need replacement after prolonged use. If there is a
need for service, only authorized representatives should perform the work.
Always supply water with a low mineral count that meets the standards outlined in
the
Water Quality and Treatment section of this manual.
If steam or condensate is seen leaking from around the door, take the following steps:
1.
Check the door gasket. Replace it if it is cracked or split.
2.
Inspect the cooking chamber drain to be sure it is not blocked.
3.
Adjust the door latch pin to allow for changes that might occur as the gasket
ages.
a.
Loosen the lock nut at the base of the latch pin, then turn the latch pin
1⁄4 turn clockwise, and tighten the lock nut.
b.
After adjustment, run the unit to test for further steam leakage.
c.
If there is still leakage, repeat the adjustment.
d.
Continue adjusting the pin clockwise until the door fits tightly enough to
prevent leakage. The hinge may also be adjusted.