Cleaning
2.
Steam Generator and Cooking Chamber
On a regularly scheduled basis, or if the SERVICE light is on, follow the
simple de-liming instructions below. This procedure should be followed
for each cavity.
REMEMBER: DON’T ALLOW DE-LIMING AGENTS TO
MIX WITH DE-GREASERS.
a.
Ensure that the unit is turned on.
b.
Set the timer to “OFF”.
c.
Using a glove or towel for hand protection, carefully open the
deliming port. The port may be hot, and a small amount of
pressureless steam may escape as you open the port.
d.
Add two cups of de-liming agent.
e.
Close the deliming port cover.
f.
Holding in the “CLEAN” button, press and release the ON button.
g.
The clean cycle will start, and take approximately 30 minutes.
h.
When the cleaning cycle is complete, the CLEANING light will flash
and the unit will beep.
i.
Wipe out the inside of the steamer cavity.
j.
If the steamer is to be used, turn the “ON” switch on. When READY
light turns on, the steamer is ready for operation, set the timer to
the “ON” position.
NOTES:
1.
If the clean cycle ends abruptly, the CLEANING light will flash five times
per second. This indicates that the clean cycle was aborted.
2.
In the event of a power outage during a clean cycle, rerun the clean cycle
when the power is restored.
3.
To abort a clean cycle, turn the “ON” switch off for one second and turn it
back on.
REMEMBER, DELIMING AGENT MAY STILL BE PRESENT IN
THE STEAM GENERATOR.
If the SERVICE light is on:
1.
Take the actions listed in Troubleshooting Section of this manual. Turn the
steamer off for 10 seconds and then re-start.
2.