beautypg.com

Installation, Oven description and specifications – Blodgett Mark V-100 XCEL User Manual

Page 4

background image

2

Installation

Oven Description and Specifications

electrical ratinGS- mkv1xl/aa

voltaGe

hz

kW

PhaSe

max loaD (amPS

motor

L1

L2

L3

N

U.S. and canadian installations

208

60

11.0

1

53

53

6 AWG

208

60

11.0

3

33

28

33

8 AWG

220-240

60

11.0

1

50

50

6 AWG

220-240

60

11.0

3

28

23

28

8 AWG

440

60

11.0

3

16

13

16

12 AWG

480

60

11.0

3

15

12

15

12 AWG

General export installations

220-240

50

11.0

1

50

50

Size per local code

220/380

50

11.0

3

17

15

15

4

Size per local code

240/415

50

11.0

3

19

14

14

5

Size per local code

230/400

50

11.0

3

19

14

14

5

Size per local code

Cooking in a convection oven differs from cooking in a

conventional deck or range oven since heated air is con-

stantly recirculated over the product by a fan in an en-

closed chamber. The moving air continually strips away

the layer of cool air surrounding the product, quickly al-

lowing the heat to penetrate. The result is a high qual-

ity product, cooked at a lower temperature in a shorter

amount of time.

Blodgett convection ovens represent the latest advance-

ment in energy efficiency, reliability, and ease of opera-

tion. Heat normally lost, is recirculated within the cooking

chamber before being vented from the oven: resulting in

substantial reductions in energy consumption and en-

hanced oven performance.

Air Flow Pattern for Mark V-100 XCEL

Figure 1