beautypg.com

Installation, Electrical connection – Blodgett Mark V-100 XCEL User Manual

Page 10

background image

8

Installation

electrical connection

Wiring diagrams are located in the control compartment

and on the back of the oven.
The electric motor, indicator lights and related switches

are connected to the oven as follows:
1. Remove the bottom trim and control panel covers.

Slide the control panel forward.

2. Connect the supply conduit to the wire duct located

in the lower left hand corner on the back of the oven.

3. Run the supply wires through the duct to the front of

the oven.

4. Connect the supply wires to top of right contactor in

the control compartment at the lower right corner of

the oven.

5. Reinstall the bottom trim and control panel covers.
NOTE: To prevent damage there is no power to the

heating elements when the blower is not operat-

ing.

THE BLODGETT OVEN COMPANY CANNOT ASSUME

RESPONSIBILITY FOR LOSS OR DAMAGE SUFFERED

AS A RESULT OF IMPROPER INSTALLATION.

Install incoming

power on this

contactor

Figure 7