8 at-8600, 1 vlan information window, At-8600 – Allied Telesis AT-VIEW PLUS 3.2 VLAN MANAGER User Manual
Page 45

Allied Telesyn
AT-VIEW PLUS
VLAN MANAGER
6.8 AT-8600
Topics:
•
•
6.8.1 VLAN Information Window
The VLAN Information Window displays the following attributes for each VLAN definition:
Column Name
Description
Name
This is the name of the VLAN.
Identifier
This is the unique identifier of the VLAN.
Operation Mode
This indicates the operation mode of the VLAN.
Tagged Ports
This is a list of the tagged member ports of the VLAN.
Untagged Ports
This is a list of the untagged member ports of the VLAN.
Uplink Port
This is a list of the uplink ports of the VLAN.
Private Ports
This is a list of the private ports of the VLAN.
Status
This indicates the status of the VLAN.
•
dynamic
•
static
Note
- When importing the default VLAN, VLAN Manager disregards the values specified for
Untagged Ports.
Note
- When performing an Import VLAN operation, if the specified Operation Mode is Normal
or Protected, the Uplink Ports and Private Ports fields will be ignored by the application.
Note
- When two Private VLANs specify the same Uplink port (Uplink port is untagged for the
first Private VLAN and tagged for the second Private VLAN), modifying the Private VLAN that
has the untagged Uplink port will result in the error message: "
uplink, more than one Uplink is not permitted." All ports in that Private VLAN will then be
deleted.
Note
- A GBIC image is always visible on the GBIC slot of the AT-A47 expansion module
image even if there is no GBIC physically inserted. Furthermore, the GBIC image will always
show an SC port regardless of the actual type of GBIC used.
PN 613-50666-00 Rev C
Page 45 of 59