System set port – Allied Telesis AT-S97 User Manual
Page 87

AT-S85 and AT-S97 Management Software Command Line Interface User’s Guide
87
SYSTEM SET PORT
Syntax
system set port id=
c
/
m
|
b/
[
pp
]/[
port
]
port-state=disable|enable auto-neg=disable|enable
speed=10|100|1000 duplex=half|full
crossover=mdi|mdix
ingress-rate-limit=none|128k|256k|512k|1m|2M|4M|8M
egress-rate-limit=none|128k|256k|512k|1m|2M|4M|8M
Parameters
id
Specifies a twisted pair or fiber optic port on a media
converter module. You can configure one port at a time, all
the ports of the same type (that is, twisted pair or fiber optic
ports), one port pair, and all of the ports on a module. The
ID consists of the following parts:
c
Identifies the ID number of the chassis with the
module to reset. The chassis ID number
depends on which module is installed in the
management slot of the chassis. When a
management module is installed in this slot, the
chassis ID number is 0 or 31. When a stacking
module is installed in this slot, the chassis ID
can be from 1 to 30.
m
Specifies the 10/100/100Base-T port on the
management module.
b
Specifies a slot number of a media converter
slot. In the AT-MCF2000 Chassis, the left slot is
1 and the right slot is 2.
pp
Specifies the number of the channel on the
AT-MCF2012LC and AT-MCF2012LC/1
Modules with the port to be configured. To
configure all the ports of the same type, either
twisted pair or fiber optic ports, omit this
parameter. Possible values are:
1 to 12
Specifies a channel. Channel 1
consists of twisted pair port 1 and
fiber topic port 1, channel 2 of twisted
pair port 2 and fiber topic port 2, and
so on. You can specify only one
channel.