beautypg.com

Maximum distance, Cable requirements, Port pinouts – Allied Telesis x510 Series User Manual

Page 24: Maximum distance cable requirements port pinouts

background image

Chapter 1: Overview

24

The MDI and MDI-X settings do not apply when ports are operating at
1000 Mbps.

Maximum

Distance

The ports have a maximum operating distance of 100 meters (328 feet).

Cable

Requirements

The cable requirements of the ports are given in Table 1.

Note

For the cable requirements for the ports on the AT-x510-28GPX and
AT-x510-52GPX Switches for PoE devices, refer to Table 3 on
page 26

Port Pinouts

Refer to Table 19 on page 117 and Table 20 on page 118 for the port
pinouts of the 10/100/1000Base-T twisted pair ports.

Table 1. Twisted Pair Cable for the 10/100/1000Base-T Ports

Cable Type

10Mbps

100Mbps

1000Mbps

Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.

Yes

Yes

No

Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.

Yes

Yes

Yes

Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.

Yes

Yes

Yes